BRAND | Dehn |
Product | 900367 / DVA CSP 3P 100 S FM |
Description | Downloader |
Internal code | IMP4791471 |
Custom code | 85363090 |
Technical specification | SPD according to EN 61643-11/... IEC 61643-11 Type 1 + Type 2/Class I + Class II Energy-coordinated protection effectiveness for users final (≤ 5 m) Type 1 + Type 2 + Type 3 Nominal voltage AC (UN) 230/400 V (50/60 Hz) Maximum continuous voltage AC [L-N] (UC) 255 V (50/60 Hz) Lightning pulse current (10/350) [L-N]/[N-PE] (Iimp) 25/100 kA Nominal discharge pulse current (8/20) (In) 25/100 kA Protection level [L-N]/[N-PE] (UP) ≤ 1.5 kV/≤ 1.5 kV Subsequent current network extinction [L-N]/[N-PE] (Ifi) 25 kAeff/100 Aeff Subsequent network current limitation/selectivity: a 35 A gL/gg fuse does not operate up to 25 kAeff (pres.) Operating time (tA) ≤ 100 ns Max. protection fuse (L) up to IK = 25 kAeff 250 A gG TOV voltage [L-N] (UT) — Characteristic 440 V/120 min. - hold TOV [N-PE] voltage (UT) — Characteristic 1200 V/200 ms - tightness Operating temperature [in derivation]/[through] (TU) -40°C... +80°C Operating indication/ fault green/ red Number of doors 1 Connection section (L, N, PE) (max.) 35 mm2 semi-rigid/35 mm 2 flexible Mounting on a 35 mm profile rail according to EN 60715 Thermoplastic housing material, color red, UL 94 V-0 Indoor mounting location Degree of protection IP 20 Dimensions 4 TE, DIN 43880 KEMA approvals FM contact/ exchange contact form AC flow rate 250 V/0.5 A DC flow rate 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A Connection section for FM terminals max. 1.5 mm2 rigid/flexible |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Dehn - 900367 / DVA CSP 3P 100 S FM Downloader number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Latvia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Protection Module
surge protector 230/400v
Combined arrester 1 / I DEHNventil M TT 255 FM Lightning current and surge arrester according to EN 61643-11 / IEC 61643-1 / -11 Lightning surge current (10/350) 25/100 n Maximum continuous voltage 255 V AC max.zul.Vorsicherung: 315 / 125A gL / gG Follow current extinguishing capacity: 50 kA rms Protection level: <1.5 kV FM Contact: 1 W Series installation device: 3 + 1 8 TE Protection: IP20
Isolating spark gap
(Kaps) max was 20 275 65 Kam Kam
fuse holder
fuse holder
order N 919 506
Basisteil 4-polig zur Aufnahme eines Ableitermoduls BLITZDUCTOR XT/XTU
Kombiableiter-Modul für 1 Doppelader BLITZDUCTOR XT mit LifeCheck
Phase comparator DEHNcap
Surge Protection Device
combined arrestor
Type 1 + type 2 for DEHNvalve M
Combination arrester module
interface converter USB, RS-485
Voltage tester
Surge Protection Device