BRAND | Calectro |
Product | CPS-D-A |
Description | differential pressure transmitter |
Internal code | IMP3366557 |
Weight | 0.092 |
Custom code | 90321020 |
Technical specification | Calectro differential pressure transmitter-100... +3500 Pa with display The CPS-D-A pressure sensor has a built-in differential pressure element, which for a high Accuracy and linearity are temperature-compensated. The differential pressure element and the output signal have a high resolution, which means that the pressure value is in steps of max. 1 Pa over the entire Measurement range (-100 to + 3500Pa) is presented. The desired function and measurement range are determined by set an illuminated display. The pressure measurement range determines at which measurement value the Start the output signal and when the maximum output signal should be given. output signal (0- 10V or 4-20 mA), K factor for volume measurement and the desired signal attenuation are also set via the display. CPS-D-A is manufactured from the factory for differential pressure measurement in the range 0-500 Pa, 0-10V output signal and medium signal attenuation (10 sec.) delivered. The measurement range can be indiscriminate from - 100 Pa to +3500 Pa, in steps of 50 Pa. CPS-D-A can measure volume/flow rate by setting the kFactor using, for example, blowers or measurement panels. The conversion formula The differential pressure in volume is: q = k x?? p. The K factor can be set with two decimals become. In addition, various units can be set: m³/h, m³//s and l/s. The The unit setting is only a display label and therefore does not perform a mathematical calculation of Measurement off. The measurement range can be indiscriminately from 0 to 32000, in steps of 100 to 3500 and in Steps of 500 from 3500 can be set. TECHNICAL DATA Supply voltage: 24V AC/DC ± 10% power consumption: 43 mA Output signal: 0-10V (>5 k? imp.) /4-20 mA Average attenuation: 3.10 or 20 sec Pressure ranges: Adjustable from -100 to +3500 Pa, in steps of 50 Pa Volume ranges: adjustable from 0 to +32000, in steps of 100 to 3500 and in steps of 500 from 3500 - Selectable standard symbols on the display: m³/h, m³//sec or l/sec - K factor: 0-9999.99 Accuracy: Normally ± 1% of measured pressure (@ <-100 Pa/>+100 Pa) Display: graphical LCD with backlight Ambient temperature: -20 to +50°C Cable inputs: 1xM16, 5-10 mm cable dimensions (WxHxD): 78 x90x40 m Weight: 92g 2 m hose and 2 nipples Protection class: IP54 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Calectro - CPS-D-A differential pressure transmitter number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Latvia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Fire alarm switch
air duct smoke switch 24 V AC/DC
Venturi-Rohr Länge 600 mm für UG-5
console
Transparent cover for optical smoke detector
protective housing
Steuergerät
Differential pressure transmitter -50 - +3500 Pa
smoke detector
Complete unit including the alarm inside it
venturi tube
Air duct smoke detector 24 V AC/DC
Leakage alarm for electrically conductive liquids
air duct smoke switch
Smoke detector base
pressure differentrial
Channel smoke detector
Replacement smoke alarm UG-5
Inherence sensor tape
Channel smoke switch
air duct smoke switch